Mega Power Generator Sets (24kW – 60kW)

Category:

Specification

Bore and stroke 100 X 115 mm (36 KW/ 39.6 KW)
100 X 115 mm (36 KW/ 39.6 KW)
100 X 115 mm (50 KW/ 55 KW)
105 x 125 mm (67 KW/ 74 KW)
105 x 125 mm (67 KW/ 74 KW)
Displacement 3.6 L (36 KW/ 39.6 KW)
3.6 L (36 KW/ 39.6 KW)
3.6 L (50 KW/ 55 KW)
4.33 L (67 KW/ 74 KW)
4.33 L (67 KW/ 74 KW)
Cylinder Number 4
Compression Ratio 16.4:1
Governor Method Mechanical
Aspiration Natural Aspiration & Turbo
Emission Standard

 

MAIN DIMENSIONS & WEIGHT (mm & kg)
Genset Model Length Width Height Weight
24 GF 2100 900 1150 950
30 GF 2100 900 1150 1000
40 GF 2250 900 1200 1050
50 GF 2400 900 1200 1350
60 GF 2400 900 1200 1400

Ratings

 

GENSET
Model 24 GF 30 GF 40 GF 50 GF 60 GF
Standby Output (KW/KVA) 26.4 KW/ 33 KVA 33 KW/ 41.25 KVA 44 KW/ 55KVA 55KW/ 68.75 KVA 66 KW/ 82.5 KVA
Prime Output (KW/KVA) 24 KW/ 30 KVA 30 KW/ 37.5 KVA 40 KW/ 50 KVA 50 KW/ 62.5 KVA 60 KW/ 75 KVA
Voltage 220 V (Other Voltage Accept such as 440V, 480V)
Phase 3 Phase / (1- Phase as optional)
Rated Power Factor 0.8 or (1.0)
Frequency 60 Hz
Maximum Output Current (A) @ 1ø, 220V 79 A 98 A 131 A 164 A 197 A
Type SUPERSILENT ( ≤ 75 dBA Noise level (A) @ 7m)

 

ENGINE
Brand MEGAPOWER
Rated/ Maximum Output (KW) 36 KW/ 39.6 KW 36 KW/ 39.6 KW 50 KW/ 55 KW 67 KW/ 74 KW 67 KW/ 74 KW
Rated Speed 1800 RPM
No. of Cylinders 4
Type Water-cooled, in-line 4-cycle, direct injection
Air intake method Natural Aspiration Natural Aspiration TURBO TURBO TURBO
Bore & Stroke (mm) 100 x 115 mm 100 x 115 mm 100 x 115 mm 105 x 125 mm 105 x125 mm
Compression ratio 18:01
Fuel Consumption @ 100% load 6 L/hr 6 L/hr 10 L/hr 13 L/hr 15.5 L/hr
Displacement (Liters) 3.6 L 3.6 L 3.6 L 4.33 L 4.33 L
Distilled Water/ Coolant Capacity (Liters) 16 L 16 L 16 L 17 L 17 L
Exhaust Highest Temperature (˚C) ≤ 600
Lube-oil pan capacity (Liters) 7.25 L 7.25 L 7.25 L 9 L 9 L
Voltage for start (V) 12V
Governor Method Mechanical

 

ALTERNATOR
Brand MEGA
Excitation Bruthless
Insulation Class H
Protection Class IP22
Connection Type Re-connectable
Voltage Regulation ≤ 1.5%
Waveform Distortion No load <1.5% & non-distorting balanced linear load < 5%
THF/ TIF < 2%/50%

Features

Control Module Specifications
The GU3311 is an Auto Mains Failure Control Module

– Back-lit LCD display
– 3 Phase generator and 3 Phase Mains monitoring
– Monitoring speed, frequency, voltage, current, oil pressure, coolant temperature and fuel level
– Display warning, shutdown and engine status information
– Hours counter provides accurate information for monitoring and maintenance

Remarks
Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous tested (as defined in 8528-3).

Standard Reference Conditions
Note: Standard reference conditions of 25 ˚C (77 ˚F) Air Inlet Temp, at 100 m (328 ft.) A. S. L. With 30% relative humidity. The fuel consumption data are at full load with diesel fuel with specific gravity of 0.85 and in compliance with to BS2869: 1998, Class A2.

Data Sheet

Case Study

Optional Equipment