Mega Power Generator Sets (80kW – 140kW)

Category:

Specification

Bore and stroke 105 x 125 mm (100 KW/110 KW)
105 x 130 mm (132 KW/ 145 KW)
105 x 130 mm (132 KW/ 145 KW)
105 x 135 mm (158 KW/ 173 KW)
Displacement 2.1 L
Cylinder Number 4
Compression Ratio 18:01/ 1
Governor Method Mechanical
Aspiration Natural Aspiration
Emission Standard

 

MAIN DIMENSIONS & WEIGHT (mm & kg)
Genset Model Length Width Height Weight
80 GF 2750 1050 1400 1600
100 GF 2750 1050 1400 1700
120 GF 2900 1050 1400 1850
140 GF 2900 1050 1400 1900

Ratings

 

GENSET
Model 80 GF 100 GF 120 GF 140 GF
Standby Output (KW/KVA) 88KW/ 110 KVA 110KW/ 137.5 KVA 132 KW/ 165 KVA 154 KW/ 192.5 KVA
Prime Output (KW/KVA) 80 KW/ 100 KVA 100 KW/ 125 KVA 120 KW/ 150 KVA 140 KW/ 174 KVA
Voltage 220 V (Other Voltage Accept such as 440V, 480V)
Phase 3 Phase / (1-Phase as optional)
Rated Power Factor 0.8 or (1.0)
Frequency 60 Hz
Maximum Output Current (A) @ 1ø, 220V 262 A 328 A 393 A 459 A
Type SUPERSILENT

 

ENGINE
Brand MEGAPOWER
Rated/ Maximum Output (KW) 100 KW/ 110 KW 132 KW/ 145 KW 132 KW/ 145 KW 157 KW/ 173 KW
Rated Speed 1800 RPM
No. of Cylinders 6
Type Water-cooled, in-line 4-cycle, direct injection
Air intake method TURBO TURBO/ AFTERCOOLED TURBO/ AFTERCOOLED TURBO/ AFTERCOOLED
Bore & Stroke (mm) 105 x 125 mm 105 x 130 mm 105 x 130 mm 105 x 135 mm
Compression ratio 16.4:1
Fuel Consumption @ 100% load 20 L/hr 25.8 L/hr 31 L/hr 36.20 L/hr
Displacement (Liters) 6.49 L 6.75 L 6.75 L 7 L
Distilled Water/ Coolant Capacity (Liters) 28 L 28 L 28 L 28 L
Exhaust Highest Temperature (˚C) ≤620
Lube-oil pan capacity (Liters) 13 L 13 L 13 L 18 L
Voltage for start (V) 24V
Governor Method Mechanical

 

ALTERNATOR
Brand MEGA
Excitation Bruthless
Insulation Class H
Protection Class IP22
Connection Type Re-connectable
Voltage Regulation ≤ 1.5%
Waveform Distortion No load <1.5% & non-distorting balanced linear load < 5%
THF/ TIF < 2%/50%

Features

Control Module Specifications
The GU3311 is an Auto Mains Failure Control Module

– Back-lit LCD display
– 3 Phase generator and 3 Phase Mains monitoring
– Monitoring speed, frequency, voltage, current, oil pressure, coolant temperature and fuel level
– Display warning, shutdown and engine status information
– Hours counter provides accurate information for monitoring and maintenance

Remarks
Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous tested (as defined in ISO 8528-3).

Standard Reference Conditions
Note: Standard reference conditions of 25 ˚C (77 ˚F) Air Inlet Temp, at 100 m (328 ft.) A. S. L. With 30% relative humidity. The fuel consumption data are at full load with diesel fuel with specific gravity of 0.85 and in compliance with to BS2869: 1998, Class A2.

Data Sheet

Case Study

Optional Equipment